1
Router modules
SYSLOG: May 28 16:22:35:<13>May 28 16:22:35 System: Module was inserted to slot 7
Module 7 is -d class, it can't work when router mpls is enabled.
Reset slot 7
SYSLOG: May 28 16:22:48 :<13>May 28 16:22:48 Module 7 is reset by mgmt (reason:
boot to interactive mode)
Power supply requirements for NI-MLX-10Gx8-M and NI-MLX-10Gx8-D modules
Table 14
10 Gbps interface modules (NI-MLX-10Gx8-M and NI-MLX-10Gx8-D).
TABLE 14
Router type
MLXe-4
MLX-4 and
Brocade NetIron
XMR 4000
MLXe-8
Brocade NetIron
XMR 8000
All 16-slot routers sixteen
All 32-slot routers thirty-two
24-port 1 Gbps Ethernet copper RJ45 interface module
The 24-port 1 Gbps Ethernet copper interface module is available in the following formats:
This module has 32 Mb of flash memory and contains 24 RJ45 physical ports, through which you
can connect your router to other network routers. BR-MLX-1GCx24-X-ML support s up to 512K IPv4
routes in hardware and BR-MLX-1GCx24-X version supports up to 1M IPv4 routes in hardware.
BR-MLX-1GCx24-X-ML does not include a software license, but can be upgraded to an X version
through a software license. Please contact Brocade to purchase the license upgrade.
36
lists the power supply requirements for each type of router when installing Gen-2 8-port
Power supply requirements for Gen-2 8-port 10 Gbps interface modules
Number of Gen-2
8-port 10 Gbps
interface modules
installed
three
four
four
seven
eight
eight
BR-MLX-1GCx24-X-ML
BR-MLX-1GCx24-X
Power supply requirements
one 1200W PSU
for 1+1 redundancy, install two 1200W PSU
two 1200W PSU
for 2+2 redundancy, install four 1200W PSU
one 1200W PSU
for 1+1 redundancy, install two 1200W PSU
two 1200W PSU
for 2+2 redundancy, install four 1200W PSU
three 1200W PSU
for 3+1 redundancy, install four 1200W PSU
two 1200W PSU
for 2+2 redundancy, install eight 1200W PSU
four 1200W PSU
for 4+4 redundancy, install eight 1200W PSU
four 2400W PSU
for 4+4 redundancy, install eight 2400W PSU