Basic LAG configuration example

This example shows configuring the S-Series switch to support LAGs to a server and to a Layer 2 switch.
Figure 11-127. LAG Example Network Diagram
1. Use the
Figure 11-130 on page
2. Create LAG 10.
Figure 11-128. Creating LAG 10
Force10 #config
Force10 (Config)#interface port-channel 10
Force10 (conf-if-po-10)#no shutdown
Force10 (conf-if-po-10)#channel-member 1/0/2-1/0/3
Force10 (conf-if-po-10)#protocol static
Force10 (conf-if-po-10)#exit
3. Create LAG 20.
Figure 11-129. Creating LAG 20
Force10 (Config)#interface port-channel 20
Force10 (conf-if-po-10)#no shutdown
Force10 (conf-if-po-20)#channel-member 1/0/8,1/0/9
Force10 (conf-if-po-20)#exit
172
|
Link Aggregation
show interface port-channel brief
173). This example assumes that IDs 10 and 20 are available.