Figure 5-64. Using the show bootvar Command within a Stack
Force10-S50 #boot system 2 image2
Activating image image2 ..
Force10-S50 #show bootvar
Image Descriptions
image1 : default image
image2 :
Images currently available on Flash
--------------------------------------------------------------------
unit
image1
--------------------------------------------------------------------
1
F.10.20.1
<none>
2
F.10.16.2
F.10.20.1
2. After executing the
the stack is running the new code
Figure 5-65. Verifying Stack Sequencing after a Reload with show switch and show stack
Commands
Force10-S50 #reload 2
Are you sure you want to reload the switch? (y/n) y
Reloading switch 2.
................
Force10-S50 #STACK: master on 0:1:e8:d5:c2:21 (2 cpus, 12 units)
Trying to attach more units.....
STACK: master on 0:1:e8:d5:c2:21 (2 cpus, 12 units)
STACK: attach 7 units on 1 cpu
This switch is manager of the stack.
Force10-S50 >show switch
Management
Switch
Status
------ ------------ ---------------- ---------------- --------------- --------
1
Mgmt Switch
SA-01-GE-48T
2
Stack Member SA-01-GE-48T
Force10-S50 #show stack
Stack
Stack
Unit
Interface
---- ---------------- ---------- ---------- ------------ ------------
1
Stack Port A
1
Stack Port B
2
Stack Port A
2
Stack Port B
image2
current-active
image1
image1 image2
reload 2 command to reboot Unit 2, use the show switch command to verify that
:
Preconfig
Plugged-in
Model ID
Model ID
SA-01-GE-48T
SA-01-GE-48T
Configured
Running
Link
Link
Mode
Mode
N/A
Stack
N/A
Stack
N/A
Stack
N/A
Stack
next-active
image1
Switch
Status
OK
OK
Status
Speed (Gb/s)
Link Up
10
Link Up
10
Link Up
10
Link Up
10
Code
Version
F.10.20.1
F.10.20.1