Configuring A Vlan Tunnel (Dvlan Or Vlan-Stack); Dvlan Tagging Considerations; Dvlan Configuration Sequence - Dell Force10 S2410-01-10GE-24P Configuration Manual

Sftos configuration guide
Hide thumbs Also See for Force10 S2410-01-10GE-24P:
Table of Contents

Advertisement

Configuring a VLAN Tunnel (DVLAN or VLAN-Stack)

Note: VLAN stacking functionality existed in SFTOS prior to SFTOS 2.5.2.0, but it was not
tested in SFTOS 2.5.2.0, so it is not supported in versions after SFTOS 2.5.1.13.
VLAN stacking, also called Double VLAN (DVLAN) and QinQ, support VLAN tunneling. In more detail,
with the VLAN-Stack feature, you can "stack" VLANs into one tunnel and switch them through the
network. This feature is a way to pass VLAN traffic from one customer domain to another through a metro
core in a simple, cost-effective manner.
The additional tag on the traffic helps differentiate between customers in the MAN while preserving the
VLAN identification of the individual customers when the traffic enters their own 802.1Q domains. The
4-byte tag precedes the VLAN tag and carries:
Protocol ID (Ethertype field)
Customer ID (VLAN ID field)

DVLAN Tagging Considerations

Frame size: If the port is enabled for DVLAN tagging and maximum length frames are expected,
jumbo frame support should also be enabled (Use the
Port types: DVLAN tagging may be enabled for a LAG, but not for LAG members, VLAN routing
ports, or probe ports.
Control frames: Control frames (e.g. GARP, LACPDUs) will be double-tagged.
Ethertypes for DVLAN tags ("DVLAN tag" is sometimes shortened to DVT):
802.1Q tag (0x8100)
vMAN tag (0x88A8)
Custom tag (any valid value)
The tunnel port (core port; uplink port) cannot be a routed port.
After the outer tag is added, QoS on the inner tag is not supported.

DVLAN Configuration Sequence

If you have created the required VLANs and you want to associate access and trunk ports with a particular
DVLAN bridging instance, you must enable the system for double VLAN tagging, define the access and
trunk ports, and then enable tagging on the trunk (core) port.
Step
Command Syntax
1
dvlan-tunnel ethertype
vman | custom
2
interface
unit/slot/port
{
802.1Q |
}
0-65535
command in Interface Config mode).
mtu
Command Mode
Purpose
Global Config
Enables the system for double VLAN
tagging with selected tagging.
Global Config
By default, all ports become trunk (core)
ports. Select a port to configure as an access
port.