Customer Support Information

Installation and Operational Procedures

— The facility interface code (FIC) and service order code (SOC):
— The quantities and USOC numbers of the jacks required.
— For each jack, the sequence in which lines are to be connected, the line
Ringer Equivalence Number (REN). The REN is used to determine the
number of devices that may be connected to the telephone line. Excessive
RENs on the line may result in the devices not ringing in response to an
incoming call. In most, but not all, areas the sum of the RENs should not
exceed five (5.0). To be certain of the number of devices that may be
connected to the line, as determined by the total RENs, contact the local
telephone company to determine the maximum REN for the calling area.
Disconnection. You must also notify your local telephone company if and
when this equipment is permanently disconnected from the line(s).
Installation and
Operational Procedures
The manuals for your system contain information about installation and
operational procedures.
Repair Instructions. If you experience trouble because your equipment is
malfunctioning, the FCC requires that the equipment not be used and that it
be disconnected from the network until the problem has been corrected.
Repairs to this equipment can be made only by the manufacturers, their
authorized agents, or others who may be authorized by the FCC. In the

The REN (Ringer Equivalence Number) for all three systems is 1.5A.

For tie line connection, the FIC is TL31M and the SOC is 9.0F.

For connection to off-premises stations, the FIC is OL13C and the
SOC is 9.0F.

For equipment to be connected to DID facilities, the FIC is 02RV2-T
and the SOC is AS.2.
— For equipment to be connected to 1.544-Mbps digital
service, the SOC is 6.0P and the FIC is:
— 04DU9-BN for D4 framing format with AMI zero code
suppression.
— 04DU9-DN for D4 framing format with bipolar 8 zero
code suppression (B8ZS).04DU9-IKN for extended
superframe format (ESF) with AMI zero code
suppression.
— 04DU9-ISN with ESF and B8ZS.

For equipment to be connected to 56-Kbps or 64-Kbps digital
facilities, the FIC is 02B1Q.
types, the FIC, and the REN by position when applicable.