Bri Facilities - Lucent Technologies MERLIN LEGEND Release 6.0 System Programming Manual

Communications system
Hide thumbs Also See for MERLIN LEGEND Release 6.0:
Table of Contents

Advertisement

MERLIN LEGEND Communications System Release 6.0
System Programming 555-660-111
4
Programming Procedures

BRI Facilities

BRI Facilities
The procedures in this section provide the steps for programming the following
options for Basic Rate Interface (BRI) facilities connected to an 800 NI-BRI
module:
Service Profile Identifier (SPID) and Directory Number (DN)
Timers
NOTES:
1. The 800 NI-BRI module is only available in Release 4.0 and later.
2. If you are adding BRI facilities to an existing system, clock
Service Profile Identifier (SPID) and
Directory Number (DN)
Use this procedure to program the Service Profile Identifier (SPID) and Directory
Number (DN) for each BRI line in the system. Until these values are programmed
for each line, the system considers the BRI line inactive and the line will not
initialize.
NOTE:
NOTE:
NOTE:
The system will not be forced idle when SPIDs are entered. However, if for
some reason a SPID changes, the line must be idle (no active call on the
line) in order to change the SPID.
Summary: Service Profile Identifier (SPID) and
Directory Number (DN)
Programmable by
Mode
Idle Condition
Planning Form
Factory Setting
Valid Entries
Inspect
Copy Option
synchronization must be set correctly. To inspect or change these
values, see
"Clock Synchronization" on page
System Manager
Key, Hybrid/PBX
Not required
Form 3i, Incoming Trunks: BRI Options (800 NI-BRI module)
none
SPID: up to 20 digits (any combination of 0 to 9)
DN: up to 10 digits (any combination of 0 to 9)
No
No
4