Example 2:
Specified position: Left
Selected range = Disable, Start = 0 mm, End = 300 mm or more
Specified position: Middle
Selected range = Enable, Start = 0 mm, End = 0 mm
Specified position: Right
Selected range = Disable, Start = 0 mm, End = 0 mm
35
35
35
60
60
Multifeeds are detected only for the areas in light blue.
When detecting the overlapping of documents, the multifeed
detection rate may drop if the documents are glued tightly or
attached together by static electricity.
300
Unit: mm
Example 3: (Bad example)
Specified position: Left
Selected range = Disable, Start = 310 mm, End = 400 mm
Specified position: Middle
Selected range = Enable, Start = 320 mm, End = 450 mm
Specified position: Right
Selected range = Enable, Start = 100 mm, End = 102 mm
35
35
35
60
60
Since the detection range (length) is less than 8 mm,
multifeeds cannot be detected correctly.