Chapter 9 Operational Settings
Range
End
Displays the end point of the detection by
(Left/Middle/Right)
the length from the leading edge of the
document.
Configurable area: 0 to 510 mm (in
increments of 2 mm), Start < End
When both [Start] and [End] are set to "0", multifeed
detection is performed for the whole area regardless of
whether it is enabled or disabled.
To disable multifeed detection for the whole document,
select [Disable] and set the start position to "0" and the
end position to be equal to or longer than the
document length.
If the start position is set larger than the document
length: with [Disable], the whole range covering the
entire document length will be checked; with [Enable],
the multifeed detection will be disabled.
To detect multifeeds, the detection range must be at
least 8 mm in length.
Configure the settings so that the value of the end
position minus the start position is 6 mm or more.
You can also set the start and the end positions by one
of the following ways:
- Create a square or rectangle to indicate the
detection range by dragging your mouse pointer on
the displayed image in the dialog box.
- Drag the handle for the detection range to change
the start and end positions using the mouse pointer
on the displayed image in the dialog box.
Example 1:
Description
Multifeed is detected only for the areas in light blue.
Specified position: Left
Selected range = Disable, Start = 50 mm, End = 200 mm
Specified position: Middle
Selected range = Enable, Start = 50 mm, End = 200 mm
Specified position: Right
Selected range = Disable, Start = 50 mm, End = 200 mm
35
35
35
50
60
60
Introduction
Scanner
Overview
How to Load
Documents
Configuring
the Scan
200
Settings
How to Use
the Operator
Panel
Various Ways
to Scan
Unit: mm
Daily Care
Replacing
Consumables
Troubleshooting
Operational
Settings
TOP
Contents
Index
Appendix
Glossary
211

Advertisement

Table of Contents
loading

Table of Contents