3
Adjust the offset/vertical magnification as necessary.
Offset Setting
Unit
Select [ADF (front)] or [ADF (back)] as the target
for offset adjustment.
Note that when the connection is via SCSI or
USB Connector 2, you can only adjust the offset
for [ADF (back)].
Main
Adjusts the horizontal (width) offset.
The setting range is from -2 to 3 mm in 0.5 mm
increments.
Sub
Adjusts the vertical (length) offset.
The setting range is from -2 to 3 mm in 0.5 mm
increments.
Description
Vertical magnification
Adjustment
Unit
The target for vertical
magnification adjustment is fixed
at [ADF].
Vertical magnification
Adjusts the vertical (length)
Adjustment (length)
magnification.
The setting range is from -3.1 to
3.1% in 0.1% increments.