Sun Solaris San Rules; Sun Solaris San Configuration Rules - HP StorageWorks 4000/6000/8000 - Enterprise Virtual Arrays Reference Manual

San design
Hide thumbs Also See for StorageWorks 4000/6000/8000 - Enterprise Virtual Arrays:
Table of Contents

Advertisement

Sun Solaris SAN rules

This section describes the SAN rules for Sun Solaris.
For current storage system support, see the SPOCK website at http://www.hp.com/storage/spock.
You must sign up for an HP Passport to enable access.
Table 110
describes the SAN configuration rules for Sun Solaris.
Sun Solaris multipathing coexistence.
Table 110 Sun Solaris SAN configuration rules
1
Storage systems
All supported
MSA2000fc G2
(MSA2300fc)
VA7100
XP48
VA7110
XP512
VA7400
XP128
VA7410
XP1024
EVA4000
XP10000
EVA4100
XP12000
EVA4400
XP20000
EVA6000
XP24000
EVA6100
EVA6400
EVA8000
EVA8100
EVA8400
EVA3000/
5000 nl
(VCS 4x)
Zoning is required when Solaris is used in a heterogeneous SAN with other operating systems.
Supports Veritas Cluster Server, Sun Cluster, and PRIMECLUSTER. Contact an HP storage
nl
representative for version and storage system support. Not all storage system types are supported
on all cluster solutions.
Each cluster must be in its own zone.
Supports connection of single HBA servers.
Supports multipathing high-availability configuration implemented in multiple fabrics or in a single
fabric with zoned paths.
Requires a multipathing driver for active/active or active/passive failover with two or more paths.
Zoning is required when Sun Solaris is used in a heterogeneous SAN with other operating systems.
Single path is not supported. MPxIO is required.
Retry count must be set to 10; entry in /kernel/drv/sd.conf must be set as follows:
SD-config-list="HP
MSA","retries-timeout: 10"
Note: There should be six spaces between "HP" and "MSA."
Supports boot from SAN. For more information, see
and VA SAN boot
support" on page 268.
Requires MPxIO, Veritas Volume Manager DMP, or HDLM multipathing driver. For version support,
contact an HP storage representative. See
For HP Continuous Access EVA configuration information, see
integration" on page 254.
Table 111
describes support for
Solaris SAN rules
"EVA SAN boot
Table 111
for multipathing coexistence support.
"HP Continuous Access EVA SAN
SAN Design Reference Guide
support" on page 256 and
227
"XP

Hide quick links:

Advertisement

Table of Contents
loading