Port Mirroring (continued)
Display
Switch# show mirror
Mirror Status : Enabled
Ingress Monitor Destination Port : fa6
Egress Monitor Destination Port : fa6
Ingress Source Ports :fa1,fa2,
Egress Source Ports :fa1,fa2,
Event Log
Display
Switch# show event-log
<1>Jan
<2>Jan
<3>Jan
<4>Jan
Topology Discovery (LLDP)
Enable LLDP
Switch(config)# lldp
holdtime
run
timer
Switch(config)# lldp run
LLDP is enabled!
Change LLDP
Switch(config)# lldp holdtime
timer
<10-255>
Switch(config)# lldp timer
<5-254>
Ping
Ping IP
Switch# ping 192.168.250.250
PING 192.168.250.33 (192.168. 250.250): 56 data bytes
64 bytes from 192.168. 250.250: icmp_seq=0 ttl=128 time=0.0 ms
64 bytes from 192.168. 250.250: icmp_seq=1 ttl=128 time=0.0 ms
64 bytes from 192.168. 250.250: icmp_seq=2 ttl=128 time=0.0 ms
64 bytes from 192.168. 250.250: icmp_seq=3 ttl=128 time=0.0 ms
64 bytes from 192.168. 250.250: icmp_seq=4 ttl=128 time=0.0 ms
--- 192.168. 250.250 ping statistics ---
packets transmitted, 5 packets received, 0% packet loss
round-trip min/avg/max = 0.0/0.0/0.0 ms
CLI Commands of the Monitor and Diag
1 02:50:47 snmpd[101]: Event: Link 4 Down.
1 02:50:50 snmpd[101]: Event: Link 5 Up.
1 02:50:51 snmpd[101]: Event: Link 5 Down.
1 02:50:53 snmpd[101]: Event: Link 4 Up.
Specify the holdtime of LLDP in seconds
Enable LLDP
Set the transmission frequency of LLDP in seconds
Valid range is 10~255
Valid range is 5~254