Configuring VSAN Trunking
Displaying VSAN Trunking Information
The show interface command is invoked from the EXEC mode and displays VSAN trunking configurations
for a TE port. Without any arguments, this command displays the information for all of the configured interfaces
in the switch.
The following example shows how to display the trunk mode of a Fibre Channel interface:
switch# show interface fc3/3
fc3/3 is up
...
The following example shows how to display the trunk protocol of a Fibre Channel interface:
switch# show trunk protocol
Trunk protocol is enabled
The following example shows how to display the VSAN information for all trunk interfaces:
switch# show interface trunk vsan 1-1000
fc3/1 is not trunking
...
fc3/11 is trunking
...
san-port-channel 6 is trunking
Default Trunk Configuration Settings
The following table lists the default settings for trunking parameters.
Table 69: Default Trunk Configuration Parameters
Parameters
Switch port trunk mode
Allowed VSAN list
Trunking protocol
OL-16597-01
Hardware is Fibre Channel, SFP is short wave laser w/o OFC (SN)
Port WWN is 20:83:00:0d:ec:6d:78:40
Peer port WWN is 20:0c:00:0d:ec:0d:d0:00
Admin port mode is auto, trunk mode is on
Belongs to san-port-channel 6
Vsan 1 is up, FCID is 0xef0000
Vsan 2 is up, FCID is 0xef0000
Vsan 1 is up, FCID is 0xef0000
Vsan 2 is up, FCID is 0xef0000
Default
On
1 to 4093 user-defined VSAN IDs
Enabled
Cisco Nexus 5000 Series Switch CLI Software Configuration Guide
Displaying VSAN Trunking Information
513
Need help?
Do you have a question about the AP775A - Nexus Converged Network Switch 5010 and is the answer not in the manual?
Questions and answers