Configuring Online Diagnostics

This chapter describes how to configure the generic online diagnostics (GOLD) feature. It contains the
following sections:

Information About Online Diagnostics

Online diagnostics provide verification of hardware components during switch bootup or reset, and they
monitor the health of the hardware during normal switch operation.

Online Diagnostics Overview

Cisco Nexus 5000 Series switches support bootup diagnostics and runtime diagnostics. Bootup diagnostics
include disruptive tests and nondisruptive tests that run during system bootup and system reset.
Runtime diagnostics (also known as health monitoring diagnostics) include nondisruptive tests that run in the
background during normal operation of the switch.

Bootup Diagnostics

Bootup diagnostics detect faulty hardware before bringing the switch online. Bootup diagnostics also check
the data path and control path connectivity between the supervisor and the ASICs. The following table describes
the diagnostics that are run only during switch bootup or reset.
Table 34: Bootup Diagnostics
Diagnostic
PCIe
OL-16597-01
Information About Online Diagnostics, page 329
Configuring Online Diagnostics, page 332
Verifying Online Diagnostics Configuration, page 332
Default GOLD Settings, page 332
C H A P T E R
Description
Tests PCI express (PCIe) access.
Cisco Nexus 5000 Series Switch CLI Software Configuration Guide
25
329