Timer Configuration Per-Vsan - Cisco AP775A - Nexus Converged Network Switch 5010 Configuration Manual

Cli software configuration guide
Hide thumbs Also See for AP775A - Nexus Converged Network Switch 5010:
Table of Contents

Advertisement

Timer Configuration Per-VSAN

If a VSAN is not specified when you change the timer value, the changed value is applied to all VSANs
Note
in the switch.
To configure Fibre Channel timers across all VSANs, perform this task:
Procedure
Step 1
Step 2
Timer Configuration Per-VSAN
You can also issue the fctimer for a specified VSAN to configure different TOV values for VSANs with
special links such as Fibre Channel. You can configure different E_D_TOV, R_A_TOV, and D_S_TOV
values for individual VSANs. Active VSANs are suspended and activated when their timer values are changed.
This configuration must be propagated to all switches in the fabric. Be sure to configure the same value
Note
in all switches in the fabric.
To configure per-VSAN Fibre Channel timers, perform this task:
Procedure
Step 1
Step 2
The following example configures the timer value for VSAN 2:
switch(config#)# fctimer D_S_TOV 6000 vsan 2
Warning: The vsan will be temporarily suspended when updating the timer value This
configuration would impact whole fabric. Do you want to continue? (y/n) y
Since this configuration is not propagated to other switches, please configure the same
value in all the switches
Cisco Nexus 5000 Series Switch CLI Software Configuration Guide
608
Command or Action
switch# configure terminal
switch(config)# fctimer R_A_TOV
timeout
Command or Action
switch# configuration terminal
switch(config#)# fctimer D_S_TOV
timeout vsan vsan-id
Advanced Fibre Channel Features and Concepts
Purpose
Enters configuration mode.
Configures the R_A_TOV timeout value for all VSANs.
The units is milliseconds.
This type of configuration is not permitted unless all
VSANs are suspended.
Purpose
Enters configuration mode.
Configures the D_S_TOV timeout value (in
milliseconds) for the specified VSAN. Suspends the
VSAN temporarily. You have the option to end this
command, if required.
OL-16597-01