Displaying Cfs Distribution Information - Cisco AP775A - Nexus Converged Network Switch 5010 Configuration Manual

Cli software configuration guide
Hide thumbs Also See for AP775A - Nexus Converged Network Switch 5010:
Table of Contents

Advertisement

Displaying CFS Distribution Information

Displaying CFS Distribution Information
The show cfs merge status name command displays the merge status for a given application. The following
example displays the output for an application distributing in logical scope. It shows the merge status in all
valid VSANs on the switch. The command output shows the merge status as one of the following: Success,
Waiting, or Failure or In Progress. In case of a successful merge, all the switches in the network are shown
under the local network. In case of a merge failure or a merge in progress, the local network and the remote
network involved in the merge are indicated separately. The application server in each network that is mainly
responsible for the merge is indicated by the term Merge Master.
switch# show cfs merge status name port-security
Logical [VSAN 1] Merge Status: Failed
Local Fabric
----------------------------------------------------------------
Domain Switch WWN
----------------------------------------------------------------
238
Remote Fabric
----------------------------------------------------------------
Domain Switch WWN
----------------------------------------------------------------
236
Logical [VSAN 2] Merge Status: Success
Local Fabric
----------------------------------------------------------------
Domain Switch WWN
----------------------------------------------------------------
211
1
Logical [VSAN 3] Merge Status: Success
Local Fabric
----------------------------------------------------------------
Domain Switch WWN
----------------------------------------------------------------
221
103
The following example of the show cfs merge status name command output displays an application using
the physical scope with a merge failure. The command uses the specified application name to display the
merge status based on the application scope.
switch# show cfs merge status name ntp
Physical
Local Fabric
---------------------------------------------------------
Switch WWN
---------------------------------------------------------
20:00:00:05:30:00:6b:9e
Remote Fabric
---------------------------------------------------------
Switch WWN
---------------------------------------------------------
20:00:00:0e:d7:00:3c:9e
The show cfs peers command output displays all the switches in the physical network in terms of the switch
WWN and the IP address. The local switch is indicated as Local.
switch# show cfs peers
Cisco Nexus 5000 Series Switch CLI Software Configuration Guide
312
20:00:00:05:30:00:6b:9e
20:00:00:0e:d7:00:3c:9e
20:00:00:05:30:00:6b:9e
20:00:00:0e:d7:00:3c:9e
20:00:00:05:30:00:6b:9e
20:00:00:0e:d7:00:3c:9e
Merge Status: Failed
IP Address
10.76.100.167
IP Address
10.76.100.169
IP Address
10.76.100.167
[Merge Master]
IP Address
10.76.100.169
[Merge Master]
IP Address
10.76.100.167
[Merge Master]
10.76.100.169
IP Address
10.76.100.167
[Merge Master]
10.76.100.169
[Merge Master]
[Merge Master]
Using Cisco Fabric Services