Disabling and Restarting Ethernet Interfaces
network servers through all dynamic routing protocols. When shut down, the interface is not included in any
routing updates.
To disable an interface, perform this task:
Procedure
Step 1
Step 2
Step 3
Step 4
The following example shows how to disable an Ethernet port:
switch# configure terminal
switch(config)# interface ethernet 1/4
switch(config-if)# shutdown
The following example shows how to restart an Ethernet interface:
switch# configure terminal
switch(config)# interface ethernet 1/4
switch(config-if)# no shutdown

Displaying Interface Information

To view configuration information about the defined interfaces, perform one of these tasks:
Command
switch# show interface type slot/port
switch# show interface type slot/port capabilities
switch# show interface type slot/port transceiver
switch# show interface brief
switch# show interface debounce
switch# show interface flowcontrol
Cisco Nexus 5000 Series Switch CLI Software Configuration Guide
74
Command or Action
switch# configure terminal
switch(config)# interface type slot/port
switch(config-if)# shutdown
switch(config-if)# no shutdown
Displaying Interface Information
Purpose
Enters configuration mode.
Enters interface configuration mode for the
specified interface.
Disables the interface.
Restarts the interface.
Purpose
Displays the detailed configuration of the specified
interface.
Displays detailed information about the capabilities
of the specified interface. This option is only available
for physical interfaces
Displays detailed information about the transceiver
connected to the specified interface. This option is
only available for physical interfaces.
Displays the status of all interfaces.
Displays the debounce status of all interfaces.
Displays the detailed listing of the flow control
settings on all interfaces.