Brocade Communications Systems A7533A - Brocade 4Gb SAN Switch Base Command Reference Manual page 709

Brocade fabric os command reference manual - supporting fabric os v5.3.0 (53-1000436-01, june 2007)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

Proto
ISCSI
FCIP
comment
Disabled
Bypassed
Loopback
E_Port
F_Port
G_Port
L_Port
EX_Port
Mirror Port
(Trunk master)
(Trunk port, master is port #x)
(upstream)
(downstream)
Persistently Disabled
FICON
Fabric ID conflict
Fabric ID oversubscribed
If a port is configured as a long distance port, the long distance level is displayed in the format of
Lx, where x represents the long distance level number. See portCfgLongDistance for the level
description.
The port state for disabled E_Ports display as In_Sync when the port is the interswitch link (ISL)
between a Brocade 48000 and a Brocade 24000. If the ISL is between a Brocade 48000 and a
Brocade 4100 or 200E, the disabled E_Port displays as No_Sync.
NOTE
On a Brocade 7600 switch, if the SAS image is not consistent with the FOS image, "(SAS
Virtualization Disabled)" will appear at the end of the output.
Fabric OS Command Reference Manual
53-1000436-01
Protocol support by GbE port.
Ports support ISCSI.
Ports support FCIP.
The comment field is blank, or displays:
Port is disabled.
Port is bypassed (loop only).
Port is in loopback mode.
Fabric port; displays WWN and name of attached switch. If the port is
configured as EX_Port, the WWN of the attached switch is the same as the
router.
Point-to-point port; displays WWN of attached N_Port.
Point-to-point but not yet E_Port or F_Port.
Loop port; displays number of NL_Ports.
Router port; displays WWN of the attached edge switch.
The port is a mirror port.
Port is the master port in a group of trunking ports.
Port is configured as a trunking port; the master port is port #x.
E_Port is an upstream path toward the principal switch of the fabric.
E_Port is a downstream path away from the principal switch of the fabric.
This port has been disabled using portCfgPersistentDisable.
Persistent DID
This port has been disabled since the switch could not obtain its
configuration domain ID during the fabric reconfiguration when ficonMode
was enabled. See ficonMode help page for more information.
Two different fabrics have been assigned the same fabric ID ( EX_Ports only).
One fabric has been assigned two different fabric IDs (EX_Ports only).