Brocade Communications Systems A7533A - Brocade 4Gb SAN Switch Base Command Reference Manual page 59

Brocade fabric os command reference manual - supporting fabric os v5.3.0 (53-1000436-01, june 2007)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

Trap Recipient Severity Level
The trap severity level is associated with each trap recipient IP address. The event trap level is in
conjunction with the event's severity level. When an event occurs and if its severity level is at or
below the set value, the SNMP event traps (swEventTrap, swFabricWatchTrap, and
connUnitEventTrap) are sent to the trap recipients. By default, this value is set to 0, implying that no
such traps are sent. Possible values are:
0
1
2
3
4
5
Refer to errShow for related information.
The ACL check is as follows: there are six ACLs to restrict SNMP get/set/trap operations to hosts
under a host-subnet-area. Host-subnet-area is defined by comparing nonzero IP octets. For
example, an ACL of 192.168.64.0 enables access by any hosts that start with the specified octets.
The connecting host is enabled to set each host-subnet-area to be read-write or read-only. The
highest privilege matched out of six entries is given to the access. The ACL check is turned off when
all six entries contain 0.0.0.0. The default values of all six entries are 0.0.0.0.
When secure mode is enabled, the access control list feature is incorporated into the WSNMP and
RSNMP security policies. Community strings can be changed on the primary FCS switch only and
will propagate across the fabric.
Operands
none
Examples
To modify the SNMP configuration values:
Fabric OS Command Reference Manual
53-1000436-01
none
critical
error
warning
informational
debug
switch:admin> agtcfgset
Customizing MIB-II system variables ...
At each prompt, do one of the followings:
o <Return> to accept current value,
o enter the appropriate new value,
o <Control-D> to skip the rest of configuration, or
o <Control-C> to cancel any change.
To correct any input mistake:
<Backspace> erases the previous character,
<Control-U> erases the whole line,
sysDescr: [Fibre Channel Switch.]
sysLocation: [End User Premise.]
sysContact: [Field Support.]
authTrapsEnabled (true, t, false, f): [false]
SNMP community and trap recipient configuration:
Community (rw): [Secret C0de]
Trap Recipient's IP address: [0.0.0.0] 1080::8:800:200C:1234
Community (rw): [OrigEquipMfr]
string size must be between 2 and 16 - please re-enter
2
agtCfgSet
27

Advertisement

Table of Contents
loading

Table of Contents