filterTest
-txports itemlist
-scamoff offset
-dcamoff offset
-fdefoff offset
Examples
To run a frame filter test:
Diagnostics
When it detects failures, the subtest might report one or more of the following error messages:
Refer to the Fabric OS Message Reference for more information.
See Also
itemList
234
Specify the user port numbers to perform this test. All user ports are set by
default.
Specify the program location to write SCAM test data in SCAM memory. The
default value is 0. The maximum offset number is set if the specified number
is larger than the limit.
Specify the program location to write DCAM test data in DCAM memory. The
default value is 0. The maximum offset number is set if the specified number
is larger than the limit.
Specify the program location to write filter test definition data in filter
definition memory. The default value is 0. The maximum offset number is set
if the specified number is larger than the limit.
switch:admin> filtertest -txports 3/1-3/3
Running filtertest ..............
Test Complete: filtertest Pass 1 of 1
Duration 0 hr, 0 min & 2 sec (0:0:2:679).
passed.
DIAG-ACTTEST
DIAG-FLTINIT
DIAG-FLTRCV
DIAG-FLTXMIT
DIAG-NUMTEST
Fabric OS Command Reference Manual