Brocade Communications Systems A7533A - Brocade 4Gb SAN Switch Base Command Reference Manual page 558

Brocade fabric os command reference manual - supporting fabric os v5.3.0 (53-1000436-01, june 2007)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

2
portShow
The execution of this command is subject to Admin Domain restrictions that may be in place.
Operands
This command has the following operands:
arp
fciptunnel
-perf
-params
-ipsec
ipif
iproute
iscsi
mode
slot
[ge]port
Examples
To display the state of a port:
526
Displays ARP table. Use this operand to display IP addresses, corresponding
MAC addresses, and flags.
Displays FCIP tunnel IDs, remote and local IP addresses, remote and local
WWNs, compression status, fastwrite status, tape pipelining status,
bandwidth rate, SACK status, Minimum Retransmit time, Keepalive Timeout,
Maximum Retransmissions, DSCP Marking, tunnel status, tunnel uptime, and
shows the current DiffServ markings being used for data connection as well
as control connection. You must specify all to display all FCIP tunnels or the
tunnel_id to display the specified FCIP tunnel. Additional options include:
Displays additional performance information.
Displays connection parameter information.
Displays IKE and IPSec policy information on IPSec-enabled tunnels.
Displays the IP interface, IP address, netmask, and MTU.
Displays the IP address, mask, gateway, metrics, and flags.
Displays GbE port WWN and iSCSI Sessions.
Displays the mode of the GbE port.
For bladed systems only, specify the slot number of the port to be configured,
followed by a slash (/).
Specify the port number to be displayed, relative to its slot for bladed
systems. See switchShow for a list of valid ports.
switch:admin> portshow 3
portName:
portHealth: HEALTHY
Authentication: None
portDisableReason: None
portCFlags: 0x1
portFlags: 0x4903
LOGICAL_O
NLINE LOGIN LED
portType:
10.0
POD Port: Port is licensed
portState: 1
Online
portPhys:
6
In_Sync
portScn:
64
Segmented
port generation number:
portId:
4c0300
portIfId:
43020007
portWwn:
20:03:00:05:1e:35:77:bb
portWwn of device(s) connected:
Distance:
normal
portSpeed: N2Gbps
PRESENT ACTIVE E_PORT G_PORT U_PORT SEGMENTED
26
Fabric OS Command Reference Manual
53-1000436-01