Siren Configuration; Configuring The Length Of Time The Bell Is Allowed To Function; Enabling The Internal Siren - Visonic POWERMASTER-10 - INSTALLER GUIDE Manual

Fully supervised wireless alarm control system
Hide thumbs Also See for POWERMASTER-10 - INSTALLER GUIDE:
Table of Contents

Advertisement

4.6 Siren Configuration

4.6.1 Configuring the Length of Time the Bell is allowed to Function

Here you select the length of time the bell (or siren) is allowed to function upon alarm. The bell time starts upon
activation of the siren. Once the bell time expires, the siren is automatically shut down.
Available options are: 1, 3, 4 (default), 8, 10, 15 and 20 minutes.
Note: To comply with EN requirements, the Bell Time should be set to 15 min. max.
To Configure the Length of Time the Bell is Allowed to Function
1.
DEFINE PANEL
2.
01:ENTRY DELAY 1
or
3.
4:BELL TIME
4.
bell time 4m
or
5.
6.
4:BELL TIME

4.6.2 Enabling the Internal Siren

Here you determine whether the internal siren will sound or remain silent upon alarm (according to the user
preference). Options: piezo siren on (default), piezo siren off.
To Enable the Internal Siren
1.
DEFINE PANEL
2.
01:ENTRY DELAY 1
or
3.
24:PIEZO SIREN
D-302756
For reviewing parameter configurations refer to the PowerMaster-10
Accessories Guide in section "MODIFY DEVICE SETTINGS" of the
desired device.
At the end of the procedure you can press the
perform the same procedure for a different device or you can press the
button to take you to "
Repeat steps 1 to 4 of section 4.2 "Entering the Installer Menu".
Select between "bell time 1m", "bell time 3m", "bell time 4m",
"bell time 8m", "bell time 10m", "bell time 15m" and "bell time
20m".
You can now press the
menu in "
DEFINE PANEL
".
TO EXIT
Repeat steps 1 to 4 of section 4.2 "Entering the Installer Menu".
".
<OK> TO EXIT
or
button to program any other
" or press the
button to take you to "
button and
<OK>
25

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents