Wireless; Electrical; Communication - Visonic POWERMASTER-10 - INSTALLER GUIDE Manual

Fully supervised wireless alarm control system
Hide thumbs Also See for POWERMASTER-10 - INSTALLER GUIDE:
Table of Contents

Advertisement

Data Retrieval
Real Time Clock (RTC)
Compliance with U.S.
Standards:
Compliance with European CE
Standards
GSM standards

2.2 Wireless

Frequency Band (MHz)
Antenna Type
Encryption
Protocol

2.3 Electrical

External AC/AC adapter
Current Drain
Minimum battery voltage
Backup Battery Pack
Backup Battery Pack
Battery Test

2.4 Communication

Built-in Modem
Data Transfer to Local
Computer
Report Destinations
Reporting Format Options
Pulse Rate
Message to Private Phones
D-302756
Alarm memory, trouble, event log
The control panel keeps and displays time and date. This feature is also used
for the log file by providing the date and time of each event
USA: (FCC) CFR 47part 15 and part 68
Canada: RSS 210
The PowerMaster-10 is compatible with the RTTE requirements - Directive
1999/5/EC of the European Parliament and of the Council of 9 March 1999.
According to the European standard EN50131-1, the PowerMaster-10
security grading is 2 – "low to medium risk" and environmental classification
is II – "indoor general" and the power supply type is A.
Europe: Complies with CE standards 3GPP TS 51.010-1, EN 301 511,
EN301489-7
USA: CFR 47 Part 22 (GSM850) and Part 24 (GSM 1900).
EMC standard: CFR 47 Part 15.
Europe: 433, 868, USA: 915.
Spatial diversity
AES-128
PowerG
Europe: 230VAC 50Hz input, 9VAC 700mA output.
USA: 120VAC 60Hz input, 9VAC 1000mA output.
Approx. 70 mA standby, 1600 mA peak at full load.
4.8V
Note: For CE compliance the battery backup period shall exceed 12 hours.
4.8V 1300 mAh, rechargeable NiMH battery pack, p/n GP130AAM4YMX,
manufactured by GP or equivalent
Note: For compliance with UL standards the battery backup period shall
exceed 24 hours.
4.8V 2200 mAh, rechargeable NiMH battery pack, p/n GP230AAHC4YMX,
manufactured by GP
Once every 10 seconds
300 baud, Bell 103 protocol
Via RS232 serial port
2 Monitoring Stations, 4 private telephones
SIA, Pulse 4/2 1900/1400 Hz, Pulse 4/2 1800/2300 Hz, Contact ID,
Scancom.
10, 20, 33 and 40 pps - programmable
Tone