DIAL METHOD
13.
GSM KEEP ALIVE
14.
disable
15.
or
16.
GSM KEEP ALIVE
4.7.2.2 Configuring GPRS / BB Communicators
The GSM/GPRS module is capable of communicating with the Monitoring station receiver by GPRS, GSM Voice
and SMS Channels. Each of the channels can be separately enabled or disabled in order to allow or prohibit the
module from using it for the event reporting. If all channels are enabled, the GSM/GPRS module will always try
GPRS first. If fails, it will try GSM voice. If fails, it will try any other possible method (PSTN Broadband) and only
then it will try SMS. This is due to the fact that SMS the most unreliable option of communication. Disabling any
of the GSM Module channels will cause the module to use a different sequence than the one described above.
1.
DEFINE COMM.
2.
1:PSTN/GSM
3.
2:GSM/GPRS
4.
GPRS REPORT
5.
disable
or
6.
7.
GPRS REPORT
8.
GSM REPORT
9.
disable
10.
or
11.
GSM REPORT
28
Here you prevent the GSM Service provider from disconnecting the GSM
line if the user has not initiated any outgoing telephone calls during the
last 28 days.
Select between "disable" and "every 28 days".
You can now press the
or press the
button to take you to "
Repeat steps 1 to 4 of section 4.2 "Entering the Installer Menu".
Here you determine whether the alarm system will report events to the
Monitoring Station via the GPRS Channel.
Select between "disable" and "enable".
Here you determine whether the alarm system will report events to the
Monitoring Station via the GSM Voice channel.
Select between "disable" and "enable".
button to revert to the "
<OK> TO EXIT
" menu,
AREA CODE
".