To Configure whether a missing device causes the system to become "NOT READY"
1.
DEFINE PANEL
2.
01:ENTRY DELAY 1
or
3.
16:NOT READY
4.
normal
or
5.
6.
16:NOT READY

4.8.11 Configuring the Time Period by which a Device is considered Missing

Here you determine the time limit for reception of supervision reports from various supervised wireless devices.
If any device does not report at least once within the selected time limit, an "INACTIVITY" alert is initiated.
The options are: 1, 2, 4, 8, 12 hours (default) and disable.
Note: To comply with EN requirements, 1 or 2 hours must be selected.
To Configure the Time Period by which a Device is Considered Missing
1.
DEFINE PANEL
2.
01:ENTRY DELAY 1
or
3.
15:SUPERVISION
4.
superv time 12h
or
5.
6.
15:SUPERVISION
48
Repeat steps 1 to 4 of section 4.2 "Entering the Installer Menu".
Select between "normal", and "in supervision".
You can now press the
menu in "
DEFINE PANEL
".
TO EXIT
Repeat steps 1 to 4 of section 4.2 "Entering the Installer Menu".
Select between "superv time 1h", "superv time 2h", "superv time
4h", "superv time 8h", "superv time 12h" and "disable".
You can now press the
menu in "
DEFINE PANEL
".
TO EXIT
or
button to program any other
" or press the
or
button to program any other
" or press the
button to take you to "
<OK>