Visonic POWERMASTER-10 - INSTALLER GUIDE Manual page 32

Fully supervised wireless alarm control system
Hide thumbs Also See for POWERMASTER-10 - INSTALLER GUIDE:
Table of Contents

Advertisement

Group
Alarms
Open/close
Alerts
Maintenance
"Alarm" group has the highest priority and "Alert" group has the lowest priority.
The selectable options are as follows:
Plan name
"all -o/c
backup"
"all
all"
"all-o/c
all -o/c "
"all –o/c
o/c "
"all (–alrt)
alrt"
"alrm
all (–alrm)"
"disable report"
"all
backup"
Note: "All" means that all 4 groups are reported and also trouble messages - sensor / system low battery, sensor
inactivity, power failure, jamming, communication failure etc.
4.7.3.1 Configuring the Types of Events to be Reported
1.
DEFINE COMM.
2.
1:PSTN/GSM
or
3.
3:C.S. REPORTING
4.
REPORT EVENTS
5.
all-o/c*backup
or
6.
7.
REPORT EVENTS
4.7.3.2 Configuring the Communicators Report Sequence
Continue below from the previous section or repeat steps 1 to 4 of section 4.7.3.1 before continuing with the
following instructions:
REPORT EVENTS
1.
D-302756
Abbr.
Events Reported
alrm
Fire, Burglary, Panic, Tamper
o/c
Arming AWAY, Arming HOME, Disarming
Alrt
No-activity, Emergency, Latchkey
-
Low-battery AC failure
Sent to center 1
All but open/close
All
All but open/close
All but open/close
All but alerts
Alarms
Nothing
All
Repeat steps 1 to 4 of section 4.2 "Entering the Installer Menu".
Select between "all-o/c* backup", "all
o/c*all-o/c",
"alrm*all(-alrm)", "disable report" and "all
You can now press the
" menu, or press the
METHOD
".
EXIT
Sent to center 2
All but open/close if center 1 doesn't respond
All
All but open/close
Open/close
Alerts
All but alarms
Nothing
All if cent. 1 doesn't respond
"all-o/c*o/c",
button to take you to the "
button to take you to "
*all", "all-
"all(-alrt)*alrt",
*backup".
1st RPRT
<OK> TO
31