LINE FAIL REPORT
4.7.3.8 Configuring the Event Types to be Reported to the Monitoring Station
Continue below from the previous section or repeat steps 1 to 4 of section 4.7.3.1 before continuing with the
following instructions:
REPORT EVENTS
or
1.
RPRT CNFRM ALARM
2.
disable report
3.
or
4.
RPRT CNFRM ALARM
5.
RECENT CLOSE
6.
recent cl. OFF
7.
or
8.
RECENT CLOSE
9.
ZONE RESTORE
10.
report restore
11.
or
12.
ZONE RESTORE
13.
SYS INACT REPORT
14.
38
You can now press the
menu (see Configuring Remote Programming Access Permissions), or
press the
button to take you to "
Here you determine whether the system will report whenever 2 or more
events (confirmed alarm) occur during a specific period.
Select between "disable report", "enable + bypass" and "enable
report".
Here you enable or disable the "recent closing" report, that is sent to the
Monitoring Station if an alarm occurs within 2 minutes from the expiry of
the exit delay.
Select between "recent cl. OFF" and "recent cl. ON".
Here you determine whether a zone restore will be reported or not.
Select between "report restore" and "don't report".
Here you determine whether the Monitoring Station will receive a
message if the system is inactive (not armed) during a defined period
(days).
button to take you to the "
".
<OK> TO EXIT
"