Configuring Remote Programming Access Permissions - Visonic POWERMASTER-10 - INSTALLER GUIDE Manual

Fully supervised wireless alarm control system
Hide thumbs Also See for POWERMASTER-10 - INSTALLER GUIDE:
Table of Contents

Advertisement

4.13 Configuring Remote Programming Access Permissions

1.
DEFINE COMM.
2.
1:PSTN/GSM
3.
3:C.S. REPORTING
4.
REPORT EVENTS
or
5.
PSTN UP / DOWN
6.
Remote access
7.
rem. access ON
or
8.
9.
Remote access
10.
Mast. downl code
11.
downl.code AAAA
12.
Mast. Downl code
13.
Inst. Downl code
14.
downl.code BBBB
15.
Inst. Downl code
16.
Upload option
62
Repeat steps 1 to 4 of section 4.2 "Entering the Installer Menu".
Here you give or deny permission to access the system and exercise
control from a remote telephone.
Select between "rem. access ON" and "rem. access OFF"
Here you set the master installer 4-digit password for downloading/
uploading data to/from the PowerMaster-10 memory.
Enter the 4-digit master download code ("0000" is not a valid code).
Here you set the installer 4-digit password for downloading data into the
PowerMaster-10 memory.
Attention! If "0000" is used, it will not enable connection of the
PowerMaster-10 to the PC for upload/download purpose.
Enter the 4-digit installer download code ("0000" is not a valid code).
Here you determine whether the PowerMaster-10 data can be uploaded
into a computer while the system is in disarm state or at any time (in
HOME/AWAY arming & disarm state).
D-302756