Visonic POWERMASTER-10 - INSTALLER GUIDE Manual page 19

Fully supervised wireless alarm control system
Hide thumbs Also See for POWERMASTER-10 - INSTALLER GUIDE:
Table of Contents

Advertisement

3.Home Delay
6.
Z01:SET CHIME
7.
Chime off....
or
8.
melody-chime
9.
Z01:DEV SETTINGS
10.
NEXT device
11.
MODIFY SAME Dev.
12.
EXIT Enrollment
4.5.2.2 Configuring Device Parameters
Refer to the PowerMaster-10 Accessories Guide for detailed instructions on how to modify specific device
settings for each device
4.5.2.3 Zone Types
Upon enrollment of a new detector (marked "Zxx") you must select the proper zone type. The zone type determines
how the system handles alarms and other signals sent from the device.
A list of factory defaults is printed in Appendix D. You may fill out the blank columns even before you start and
proceed to program according to your own list.
Zone types are fully explained below:
Delay Zones:
A delay zone has exit and entry delays set by you in the course of programming the system. Warning beeps will
sound throughout these delays, unless you choose to mute them.
• Exit Delay - The exit delay begins once the user arms the system. It allows him to leave via interior zones and a
doorway before arming actually takes effect. When the exit delay starts, the buzzer beeps slowly and maintains a
slow beeping rate until the last 10 seconds, during which it beeps rapidly. The PowerMaster-10 has two types of
delay zones, for which different delay times may be set.
• Entry Delay - The entry delay begins once the user enters the protected area via a specific doorway (his
entry is sensed by a delay zone detector). To avoid an alarm, he must reach the keypad via interior zones
(which become "follower zones" during the entry delay) and disarm the system before the delay expires.
When the entry delay starts, the buzzer beeps slowly until the last 10 seconds, during which it beeps rapidly.
Remember!
A delay zone is also a perimeter zone by definition.
18
To understand the behavior of each zone, see section 4.5.2.3 Zone
Types.
Press
to change chime settings or press the
Select between "Chime off" and "melody-chime".
Note: In "melody chime" mode when a chime zone is triggered, chime
melody is heard.
*
*
*
* When the PowerMaster-10 will read "
button to enroll the next device. When the PowerMaster-10 will read
"
" you can click the
MODIFY SAME Dev.
device. When the PowerMaster-10 will read "
click the
button to revert to "
" you can click the
NEXT device
button to modify the same
EXIT Enrollment
".
ADD NEW DEVICES
button to skip.
" you can
D-302756