Configuring Event Reporting To Users - Visonic POWERMASTER-10 - INSTALLER GUIDE Manual

Fully supervised wireless alarm control system
Hide thumbs Also See for POWERMASTER-10 - INSTALLER GUIDE:
Table of Contents

Advertisement

disable
15.
or
16.
SYS INACT REPORT

4.7.4 Configuring Event Reporting to Users

A. To Enable Report to Users
1.
DEFINE COMM.
2.
1:PSTN/GSM
or
3.
4:PRIVATE REPORT
4.
REPORT TO PRVT
5.
disable report
B. To Configure Event Types to be Reported to User
Here you determine which event groups will be reported to private telephone subscribers.
Term
"all"
"all (-op/cl)"
"all (-alerts)"
"alarms"
"alerts"
"op/cl"
"disable report"
Note: "All" means all events including the L. BAT and AC FAIL trouble messages.
Note: All the above options can be reported to private telephone subscribers by SMS. When Voice Report is
enabled alarms and alerts only can be reported.
The following siren signal will be sent to private telephone upon event reporting:
FIRE: ON - ON - ON - pause.... (- - - - - - ......).
BURGLAR: ON continuously (
EMERGENCY/LATCHKEY: 2-tone siren; like an ambulance.
or
6.
7.
REPORT TO PRVT
D-302756
Select between "disable", "rep. after 7d", " rep. after 14d ", "
rep. after 30d", and "rep. after 90d".
You can now press the
" menu (see section 4.7.2.1), or press the
EVENTS
you to "
<OK> TO EXIT
Repeat steps 1 to 4 of section 4.2 "Entering the Installer Menu".
Description
All messages
All messages, except open/close
All messages, except alerts
Alarm messages
Alert messages
Open/close
No message will be reported
...)
Select between "disable report", "all", "all (-op/cl)", "all(-
alerts)", "alarms", "alerts" and "op/cl".
button to take you to the "
".
REPORT
button to take
39