: This is the Ethernet address of the transceiver.
Ethernet Address
This address is fixed, and it can not be changed.
•
: This column holds the frequency and the transducer type connected.
Transducer
The left spin box is not used on the GPT transceivers.
The right spin-box is used to select transducer. The transducer must be registered in
the ES70 software to appear on this list. If you can not find your transducer on the list,
contact you dealer to upgrade the relevant software component on the ES70.
•
: This is the current status of the frequency channel.
Status
–
: The frequency channel is already in use, probably by another echo sounder
Busy
on the same network. You can not connect to this channel.
–
: This frequency channel is connected to you ES70 system.
Installed
–
: This frequency channel can not be used.
Lost
Transceiver Installation; Browsing
The
parameters are used when you wish to start an automatic search for
Browser
transceivers on the network. The communication is made between your computer
(identified with its
Local IP Address
one transceiver, you may use Point-to-Point communication mode, and enter the
transceiver's
Remote IP Address
the network for all available transceivers, choose Broadcast mode, and use the default
.
Remote IP Address
•
: This is the Internet Protocol (IP) address of the local Ethernet
Local IP Address
interface board. In most cases, each Ethernet board has a unique IP address, even
when an interface board supports multiple sockets. If you have more than one
interface board, you are provided with a list of the available addresses.
•
Remote IP Address
If the data communication is set up to receive data only, this parameter is not required.
If you wish to set up an output for broadcast, define IP address
This is the default setting.
If you set the
Communication Mode
address manually.
•
Communication mode
•
: This button initiates a search on the network for available transceivers.
Browse
Transceiver Installation; Information
If you click one of the frequency channels in the channel list, additional information about
the relevant transceiver is provided. This information is not required for operational use.
338106/A
) and one or more transceivers. If you only have
manually before you click
: Select the Internet Protocol (IP) address for the remote computer.
to Point-to-Point, you need to enter the remote IP
: Choose Broadcast or Point-to-Point.
Functions and dialogs
. If you wish to search
Browse
255.255.255.255
.
155
Need help?
Do you have a question about the ES70 - REFERENCE MANUAL REV A and is the answer not in the manual?
Questions and answers