: Once the ES70 has identified and listed all the available LAN ports on
Remove
the computer, these can not be used by any other software applications on the same
computer. However, if the ES70 does not need a specific LAN port, it can be released
for other use. Click on the applicable port to select it, then click the
delete the port from the list. Note that no acknowledgement is required, the port is
removed instantly.
: In order to use a LAN port to receive or transmit information, its
Setup
communication parameters must be set up to match the peripheral device. Click one
of the listed ports to select it, then click the
A dedicated dialog is provided.
→ LAN Port Setup on page 169
: If you suspect that the communication on the port is ineffective, faulty or
Monitor
missing, you can monitor the flow of telegrams. Click one of the listed ports to select
it, then click the
Monitor
port. A dedicated dialog is provided.
→ Port Monitor on page 171
: When you add a new port, you must define the source of the input data.
Inputs
Click the port to select it, then click the
(measuring device) you wish to import data from. A dedicated dialog is provided.
→ Select Inputs on page 172
: When you set up a port to export data, you must define the type of data to be
Output
sent out. Click the port to select it, then click the
data you wish to export. A dedicated dialog is provided.
→ Select Outputs on page 175

Transceiver Installation

The
Transceiver Installation
the
sub-menu. The
Installation
Purpose
The purpose of the
Transceiver Installation
connect the ES70 computer to the transceiver(s) and the transducer(s).
Tip
On the ES70, the parameters related to transmission and transducer depth are controlled
in the
Normal Operation
→ Normal Operation on page 121
338106/A
button to observe the data communication on the selected
Inputs
dialog is opened from the
sub-menu is in turn found on the
Installation
dialog is to set up the necessary parameters to
dialog.
Functions and dialogs
button to set up the port parameters.
Setup
button to define which external sensor
button to define what kind of
Output
Transceiver Installation
button to
Remove
button on
menu.
Setup