Can be installed in boxes 1 or 2
Can be installed together with the 8 SFF hot-plug drive cage option
Supports one SAS / SATA drive backplane option
CAUTION:
CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all bays are populated with
either a component or a blank.
CAUTION:
CAUTION: A discharge of static electricity from a finger or other conductor might damage system boards or other static-
sensitive devices. To prevent damage, observe antistatic precautions.
Procedure
Procedure
1. Back up all server data.
2. Power down the server.
3. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
4. Disconnect all peripheral cables from the server.
5. If installed, remove the front bezel .
6. Do one of the following:
If the server is in tower mode, place the server on a flat, level surface with the access panel facing up .
If the server is in rack mode, remove the server from the rack.
7. Remove the access panel .
8. Remove the system air baffle.
9. Remove the drive cage blank.
HPE ProLiant ML110 Gen11 Server User Guide