HPE ProLiant ML110 Gen11 User Manual page 214

Table of Contents

Advertisement

Specification
Specification
Input requirements
Input requirements
Rated input voltage
Rated input frequency
Rated input current
Maximum rated input power
BTUs per hour
Power supply output
Power supply output
Rated steady-state power
Maximum peak power
HPE 1600 W Flex Slot Platinum Hot-plug Low Halogen Power Supply
HPE
1600 W Flex Slot Platinum Hot-plug Low Halogen Power Supply
Specification
Specification
Input requirements
Input requirements
Rated input voltage
Rated input frequency
Rated input current
Maximum rated input power
BTUs per hour
Power supply output
Power supply output
Rated steady-state power
Maximum peak power
Value
Value
100 VAC to 127 VAC
200 VAC to 240 VAC
240 VDC for China only
50 Hz to 60 Hz
11.3 A at 100 VAC
6.1 A at 200 VAC
1130 W at 100 VAC
1090 W at 200 VAC
3764 at 100 VAC
3629 at 200 VAC
1000 W at 100 VAC to 127 VAC
1000 W at 200 VAC to 240 VAC input
1000 W at 100 VAC to 127 VAC
1000 W at 200 VAC to 240 VAC
Value
Value
200 VAC to 240 VAC
240 VDC for China only
50 Hz to 60 Hz
8.7 A at 200 VAC
7.2 A at 240 VAC
1734 W at 200 VAC
1725 W at 240 VAC
5918 at 200 VAC
5884 at 240 VAC
1600 W at 200 VAC to 240 VAC input
1600 W at 240 VDC input
1600 W for 1 ms (turbo mode) at 200 VAC to 240 VAC input
HPE ProLiant ML110 Gen11 Server User Guide