Oil Vapour Separator Replacement - Kohler KDI 2504TM Workshop Manual

Hide thumbs Also See for KDI 2504TM:
Table of Contents

Advertisement

INFORMATION FOR REPLACING THE
4. Screw the new filter G onto the pump Q (tightening
torque 20 Nm).
5. Connect the hose E to the filter G and fasten with the
clamp D.

6.8 Oil vapour separator replacement

6.8.1 Disassembly
Important
Before proceeding with operation, read
1. Release the clamp AA and remove the pipe D.
2. Release the clamps F.
3. Remove the clamp P cutting it in the point indicated
and remove the separator body C removing it from
the hose AG and G.
4. Release the clamp F.
5. Remove the pipes G and AG.
6. Undo the screws B.
7. Release the clamp S from the sleeve K.
8. Pull the flange H out of the manifold K and remove
the relevant gasket, being careful not to bend the pipe
E.
6.8.2 Assembly
Warning
Always carefully inspect the condition of the tubes,
and replace them if there is any doubt regarding their
integrity.
Always replace the gasket M after each assembly.
1. Check that the contact surface L is free from
impurities.
FUNCTIONAL UNITS
Par.
3.3.2.
Fig 6.63
Fig 6.64
Fig 6.65
6
79
EN

Hide quick links: