3Rd + 4Th Pto (Configurations) - Kohler KDI 2504TM Workshop Manual

Hide thumbs Also See for KDI 2504TM:
Table of Contents

Advertisement

INFORMATION ABOUT OPTIONAL

11.6 3rd + 4th PTO (configurations)

Fig. 11.32
11.6.1 Information
Hydraulic pumps on the 3rd and 4th PTO can be installed at the
same time.
In some configurations, there is also the centering ring C on the
4th PTO.
Important
For disassembly or installation, refer to
11.5
e
Par.
11.6.
Always replace the gasket of the rings B and C and
flanges D and K at each assembly.
Lubricate the gear H with oil.
COMPONENTS
Par.
11.4,
Par.
Fig. 11.33
11