Kohler KDI 2504TM Workshop Manual page 158

Hide thumbs Also See for KDI 2504TM:
Table of Contents

Advertisement

11
3. Position the flange K on the crankcase Q inserting the
gasket P, and insert gear N in crankcase Q.
4. Secure the flange K using the screws N (tightening
torque at 25 Nm).
Important
Always replace the gasket V after each assembly.
5. Insert the gasket V on the cover F, insert and position
the cover F on the flange K.
6. Secure the cover F using the screws E on the flange K
(tightening torque at 25 Nm)
Important
Always replace the gasket T after each assembly.
7. Position and secure the flange D using the screws C
on the crankcase S (tightening torque at 10 Nm).
Important
Always replace the gasket U after each assembly.
8. Position the gasket U on the flange D.
9. Secure the pump B using the screws A on the flange D
(tightening torque at 25 Nm).
EN
158
INFORMATION ABOUT OPTIONAL
COMPONENTS
Fig 11.28
Fig 11.29
Fig 11.30
Fig 11.31

Hide quick links:

Advertisement

Table of Contents
loading