2. Position flange H inserting hose K onto the flange
union H, being careful not to bend tube E.
3. Insert the gasket M between the flange H and the
crankcase N.
4. Secure the flange H using the screws B on the
crankcase N (tightening torque at 10 Nm).
5. Secure the clamp S on the manifold K.
6. Fit the pipes G and AG on the flange H.
7. Fit breather body C onto tubes G, AG and D and
fasten tube G - AG - D with their relative clamps.
8. Fit the breather body C on the support flange H with
the new clamp P.
EN