INFORMATION FOR DISASSEMBLY
NOTE : coupling cap F1 on the connecting rod can be carried
out with centring taper pins (Fig. 7.46b) or broken (Fig. 7.46c -
without centring taper pins).
Fig. 7.46b
Fig. 7.46c
3. Pull out the connecting rod - piston assembly from
position 2 and 3 by manually applying pressure on the
connecting rod big end L in the direction of arrow AK.
4. Couple the connecting rod big end caps L with the
relevant piston and connecting rod unit M.
5. Turn capscrew AM and rotate the crankshaft by 180°.
6. Repeat points 2 to 5 to disassemble the connecting rod-
piston assembly to position 1 and 4.
Warning
The connecting rod half-bearings Z are made of special
material. Therefore, they must be replaced every time
they are removed to prevent seizures.
Fig 7.46a
Fig 7.47
Fig 7.48
7
95
EN