Kohler KDI 2504TM Workshop Manual page 25

Hide thumbs Also See for KDI 2504TM:
Table of Contents

Advertisement

2.9.7 Guards for fuel injection circuit components
High-pressure injection circuit components are particularly
sensitive to impurities.
To prevent impurities, even microscopic ones, from accessing
the fuel input or output unions, you are required to close these
accesses by means of specific caps as soon as the various
tubes are disassembled and disconnected.
Disassembly of any component of the injection circuit must not
occur in dusty environments.
Cap guards must remain closed in their housing
the moment they are to be used.
Pay special attention when using the caps and avoid any
contamination of dust or dirt of any kind.
Even after using the caps illustrated in this paragraph, all
components of the injection circuit must be placed with care in
environments that are free of any type of impurity.
Fig. 2.11 and 2.12 illustrate the caps that must be used on
components of the injection circuit.
Cap guards must be accurately washed after use and placed
back in their housing
(ST_40).
Important
It is highly recommended to have this page visible
during disassembly operations of the components of
the fuel injection circuit.
TECHNICAL INFORMATION
(ST_40)
Fig 2.11
until
Fig 2.12
2