GENERAL INFORMATION
Type of fuel
High-pressure fuel injection pump
Fuel supply
Filtering surface
Degree of filtration
Maximum pressure at injection pump inlet
GENERAL INFORMATION
Lubrication
Circuit forced
Oil sump capacity (MAX)
Intervention pressure (MIN)
Maximum operating pressure
Degree of filtration
Filtering surface
GENERAL INFORMATION
Coolant
Water pump
Opening temperature
Stroke at 91°C
Liquid recirculation
GENERAL INFORMATION
Circuit rated voltage
External alternator (rated current)
Starter motor power
System electrical consumption, excluding:
heater, electric pump, electric fan, starter
EN
14
TECHNICAL INFORMATION
FUEL SUPPLY SYSTEM
UNIT OF
MEASURE
Fuel filter
LUBRICATION CIRCUIT
UNIT OF
MEASURE
Fuel
Oil pressure switch
Oil filter
COOLING CIRCUIT
UNIT OF
MEASURE
Lt./min
Thermostatic valve
ELECTRICAL SYSTEM - ELECTRIC FAN
UNIT OF
MEASURE
Diesel UNI-EN590 - ASTM D975
STANADYNE - DB
Low pressure electric pump
2
cm
µm
bar
Lt.
bar
bar
µm
2
cm
%
°C
mm
Lt./h
V
A
kW
W
KDI 2504 T M
2300
5
< 0.5
KDI 2504 T M
See
Par. 2.4
Lobe pump
11,5
0.8±0.1
7.0
17±2
1744
KDI 2504 T M
See
Par. 2.6
75
+79
7.50
9
KDI 2504 T M
12
80
2
24