Removing The Air Baffle Or Midplane Drive Cage - HPE ProLiant DL380 Gen10 Plus User Manual

Table of Contents

Advertisement

Removing the air baffle or midplane drive cage

Removing the air baffle or midplane drive cage
About this task
About this task
CAUTION: Do not detach the cable that connects the battery pack to the cache module. Detaching the cable causes any
CAUTION:
unsaved data in the cache module to be lost.
CAUTION: For proper cooling, do not operate the server without the access panel, baffles, expansion slot covers, or
CAUTION:
blanks installed. If the server supports hot-plug components, minimize the amount of time the access panel is open.
Procedure
Procedure
1. Power down the server.
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Do one of the following:
Extend the server from the rack .
Remove the server from the rack .
4. Remove the access panel .
5. Do one of the following:
Remove the air baffle.
Remove the midplane drive cage:
a. Disconnect all cables.
b. Remove all drives.
Be sure to note the location of each drive.
c. Remove the drive cage.
A 4LFF version is shown.
CAUTION: Do not drop the drive cage on the system board. Dropping the drive cage on the system board
CAUTION:
might damage the system or components. Remove all drives and use two hands when installing or removing
the drive cage.
Removing the air baffle or midplane drive cage
56

Advertisement

Table of Contents
loading

Table of Contents