Hardware Debug Display Screen - evertz 4025 Instruction Manual

Film footage encoder
Table of Contents

Advertisement

!
5.6.

HARDWARE DEBUG DISPLAY SCREEN

SYSTEM DIAGNOSTICS
1, 2, 3, or 4 view one of the four NOVRAM pages.
The following keys may overwrite configuration data. PROCEED WITH
CAUTION!!!
SHIFT + 0
SHIFT + 5
SHIFT + 6
SHIFT + 7
CLR
If you have changed any NOVRAM locations it is recommended that you exit
the NOVRAM view function by pressing SHIFT + 7 to reinitialize the 4025.
The Hardware Debug display screen allows viewing of hardware and
operating system related parameters. The new display is accessed by
pressing the SHIFT + TIME/UB + STATUS keys. This will bring up a full
screen video display titled "4025 HARDWARE DEBUG SCREEN". This
screen shows the following items:
DIP SW
is a hexadecimal representation of the status of the switches
located at the front of each module. The right digit pair shows
the settings for the 613 board, the centre digit pair shows the
settings for the 615 board, and the left digit pair shows the
settings for the 611 board. The left digit pair will show dashes,
since the 611 does not have switches in this application.
INPUTS
is a hexadecimal representation of the status of the parallel
inputs to the 611, 615 and 613 cards, with the right digit pair
showing the status for the 613 board, and the centre digit pair
showing the status of the 615 board parallel inputs.
BIPHASE is a hexadecimal representation of the actual biphase hardware
counter in the 4025.
meanings depending on the mode of the telecine. The number
shown is actually 4 times the tach rate of the telecine ( in
decimal notation) (i.e.: If your telecine has 10 pulses per film
frame tach rate, then the counter will change by 40 decimal (28
hex) counts for every film frame).
Model 4025 Film Footage Encoder Manual
clears all NOVRAM locations to 00
sets all NOVRAM locations to FF.
resets all NOVRAM locations to the factory defaults, and
displays page 1 of the NOVRAM.
re-initialize all the 4025 RAM parameters to the new
NOVRAM values.
exit NOVRAM VIEW mode and return to the Toolbox menu.
The value displayed has different
Page 5-9