Bts Fdl-60; Bts Fdl-90; Figure 2-11: Bts Frid Pulse Specification - evertz 4025 Instruction Manual

Film footage encoder
Table of Contents

Advertisement

INSTALLATION

Figure 2-11: BTS FRID Pulse Specification

2.11.3. BTS FDL-60

The BTS documentation for the FDL-60 shows that the FRID pulse can be
found as follows:
1.
FDL 60 A11/A13/C11/C13:
FD 353 Intermediate board/EXT 2/B25/pin 17, GND pin 18
2.
FDL 60 B1/B3/C1/C3:
FD AP DF 632-002, -003/EXT 2/B25 J34/pin 17, GND pin 18
3.
FDL 60 B2/B4 up to Serial. No. 340:
FD AP DF 632-001/FRAME ID OUT/J31/BNC with interface:
FD AP DF 632-001/EXT PAN CONTROL/B15 J35/pin 13,
GND pin 14
4.
FDL 60 B2/B4 starting with Serial. No. 341 and C2/C4:
FD AP DF 632-002, -003/EXT 2/B25 J34/pin 17, GND pin 18
TTL - output, max. current: 40 mA
Since there are a number of similar signals, we recommend that you check
out the signal with an oscilloscope while the telecine is in play.
The telecine type item on the Engineering Toolbox Hardware Menu must
be set to BTS QUADRA/FDL. (See section 3.6.4)

2.11.4. BTS FDL-90

The bi-phase tach pulse is available on the 9 pin D Sepmag connector on
the telecine. Connect pins 1 and 5 from this connector to pins 3 and 7 of
the 9 pin parallel I/O connector of the 4025 respectively. Connect ground
(pin 7 on the telecine connector to pin 6 on the 4025 connector. Note that
the pulse output should be set to 10 pulses per film frame by proper
selection of the jumper on the sprocket Pulse card in the telecine (FY806 or
FM735 card).
The FRID pulse is available on pin 17 of the External 2 25 pin D connector
on the telecine. This pulse should be connected to pin 2 pf the Parallel I/O
connector of the 4025. Ground for the FRID pulse on pin 18 of the External
Model 4025 Film Footage Encoder Manual
Page 2-22

Advertisement

Table of Contents
loading