Configuring The Operation Of The Vcg Remote Control Inputs - evertz 4025 Instruction Manual

Film footage encoder
Table of Contents

Advertisement

OPERATION
Select RUN when you want the generator to free run when there
is no incoming Reader code. When the reader code resumes,
the generator will re-jam to the incoming code. Using this mode
will allow the user to repair large dropouts in the incoming code.
The generated code will be continuous if the incoming code is
also continuous.
Select HOLD when you want the generator to stop when there
is no incoming Reader code. When the reader code resumes,
the generator will re-jam to the incoming code. Use this mode if
you want the output of the generator to stop when you stop the
tape machine supplying the incoming code to the reader.
Select OFF when you want the generator to completely turn Off
when there is no incoming Reader code. When the reader code
resumes, the generator will turn on and re-jam to the incoming
code.
3.7.8

Configuring the operation of the VCG Remote Control Inputs

VCG GPI Is used to select how the VCG remote control inputs will be
used. See section 3.12.9 for a full description of the various
remote control functions.
Select OFF to disable the remote control VCG functions.
Select TOGGLE to configure the remote control VCG inputs to
toggle the VCG displays On and Off on high to low edges of the
remote inputs.
Select EDGE
so that low to high edges turn the windows Off and high to low
edges turn the windows On.
Select EDGE
so that low to high edges turn the windows On and high to low
edges turn the windows Off.
Select LEVEL to configure the remote control VCG inputs so
that the VCG windows are Off when the inputs are LOW and On
when the inputs are HIGH. ( The Status screen will be On when
the Status input is LOW and Off when the status input is HIGH.)
When you have selected LEVEL, the front panel control of the
VCG windows is disabled.
You can only control the windows from the remote control port in the LEVEL
mode.
Model 4025 Film Footage Encoder Manual
OFF to configure the remote control VCG inputs
ON to configure the remote control VCG inputs
Page 37