5.3.
HELP MESSAGES
SYSTEM DIAGNOSTICS
KeyKode Related Messages
KK JAM: FEET DIFFERS
KK JAM: FRAMES DIFFERS
KK JAM: KEY INFO DIFFERS
KK JAM: PREFIX DIFFERS
KEYKODE OFF
KEYKODE MISSING
KEYKODE INVALID
General Messages
NO NEW PROBLEMS
GENLOCK MISSING
EVCOM RESET
STACK RESET
Time Code Related Messages
LTC FAILED VALIDATION CHK
VITC FAILED VALIDATION CHK
LTC FAILED FLAGS CHK
VITC FAILED FLAGS CHK
LTC FAILED COMPARE CHK
VITC FAILED COMPARE CHK
LTC FAILED WINDOW CHK
VITC FAILED WINDOW CHK
LTC FAILED DATA PARITY CHK
VITC FAILED DATA PARITY CHK
Model 4025 Film Footage Encoder Manual
The character generator has updated to the new
edge number.
Indicates KK JAM = OFF has been selected.
Bi-phase is indicating that the telecine is in
motion but no KeyKode is being received.
Reserved for future use.
Indicates the 611 message has been reset and
no further problems detected.
The VITC RDR IN video input is missing or
disturbed.
An inter-module communications reset
occurred, usually caused by a power on reset of
one or all the cards.
The 611 needed to do some software error
prevention - please call us if you get this
message.
The incoming timecode was rejected because
the time contained illegal numbers such as hours
> 24, minutes > 60 , etc.
The incoming timecode was rejected because
the normally static timecode flags (drop frame,
colour frame, binary group, etc.) had changed.
The incoming timecode was rejected because it
differed to much from the previous timecode
input.
The incoming timecode was rejected because it
differed to much from the previous valid
timecode.
The incoming timecode was rejected because
the parity checks failed (this is a special mode,
not normally available).
Page 5-6