Switch
Name
1
Baud Rate
2
Reserved
3
Reserved
4
Reserved
5
Reserved
6
Reserved
7
Diagnostics
8
Engineering
TECHNICAL DESCRIPTION
J11
Standard
E
EPROM Map
S
EPROM Map
21/6231 Submodule Select
FP
32/528
J8
Normal
Function when Open
Open
19200 Baud, 8 bits, even parity
Open
Open
Open
Open
Open
Open
Normal running mode
Open
Normal running mode, engineering
functions of On Screen programming
menu are disabled.
Figure 6-9: 631 Switch Definitions
DIP Switch # 7 on the 631 board enables advanced diagnostics mode
when it is in the Closed position. In this mode, several new diagnostic
features have been added.
The internal 'EV-COM' reset codes are displayed on the 'Configuring' and
'Software versions' screens. (Software versions are invoked by pressing
SHIFT+STATUS). Also visible on Hardware Debug screen ( Invoked by
TIME/UB+SHIFT+STATUS).
When the Configuring Screen appears, it will remain visible until the
CLEAR key is pressed.
Pressing SHIFT+CLEAR when the timecode windows are visible sets up
the 4025 to capture the next EV-COM reset codes.
Model 4025 Film Footage Encoder Manual
512K
27512 size EPROM
F
Single Standard EPROM
D
Dual standard EPROM
IN
Wire link installed
CUT
Board link cut
21
For use with 6121 and 6221
6231
For use with 6231 - Board link installed
IN
Wire link installed
32
Wire link installed
Wire link installed
Function when Closed
38400 Baud, 8 bits, even parity
Advanced
enabled.
power-on hardware tests that should be
disabled during normal operation.
Setup mode, engineering functions of
On Screen programming menu are
enabled.
Diagnostics
functions
These functions include
Page 6-13