Appendix D
Module Diagnostic Assembly
Table 37 - Diagnostic Assembly Instance 32775 (Continued)
Name
DiagnosticSequenceCount
OverTemperature
CriticalTemperature
DiagBits_Pad2
DiagBits_Pad3
SAPowerFault
LAPowerFault
DiagBits_Pad6
InternalFault
DiagBits_Pad8
DiagBits_Pad9
DiagBits_Pad10
DiagBits_Pad11
FlashUpdateRequired
SelfTestFault
DiagBits_Pad14
DiagBits_Pad15
ModuleStatus_Pad0
ModuleStatus_Pad1
ModuleStatus_Pad2
ModuleStatus_Pad3
ModuleStatus_Pad4
ModuleStatus_Pad5
ModuleStatus_Pad6
ModuleStatus_Pad7
DLREnabled
ModuleStatus_Pad9
ModuleStatus_Pad10
DLRNetworkState
DLRSupervisorState
LocalClockOffset
LocalClockOffsetTimestamp
GrandMasterClockID
SAPowerFaultTimestamp
LAPowerFaultTimestamp
OverTemperatureTimestamp
CriticalTemperatureTimestamp
InternalFaultTimestamp
AB:Ethernet_Port_Channel:D:0 Port1
AB:Ethernet_Port_Channel:D:0 Port2
110
Data Type
Byte
Valid Values
-128...+127
SINT
1
The value of 0 is skipped except during module power-up.
0 = Module temperature not over operating limits
BOOL
1 = Module temperature over operating limits
0 = Module not above critical temperature limit for proper operation
BOOL
1 = Module above critical temperature limit for proper operation and may shut down
without further warning
BOOL
This member acts as padding to ensure byte alignment. It can be renamed.
BOOL
This member acts as padding to ensure byte alignment. It can be renamed.
0 = No fault on SA power exists
BOOL
1 = Fault on SA power exists
0 = No fault on LA power exists
BOOL
1 = Fault on LA power exists
BOOL
This member acts as padding to ensure byte alignment. It can be renamed.
0 = No internal fault detected
2
BOOL
1 = One or more internal diagnostics indicate an internal issue in the module. Fault is
latched until the channel or device is reset
BOOL
This member acts as padding to ensure byte alignment. It can be renamed.
BOOL
This member acts as padding to ensure byte alignment. It can be renamed.
BOOL
This member acts as padding to ensure byte alignment. It can be renamed.
BOOL
This member acts as padding to ensure byte alignment. It can be renamed.
0 = Flash update not required
BOOL
1 = Module has no application firmware
0 = Module initialization code did not detect an error
BOOL
1 = Module initialization code detected an error
BOOL
This member acts as padding to ensure byte alignment. It can be renamed.
BOOL
This member acts as padding to ensure byte alignment. It can be renamed.
BOOL
This member acts as padding to ensure byte alignment. It can be renamed.
BOOL
This member acts as padding to ensure byte alignment. It can be renamed.
BOOL
This member acts as padding to ensure byte alignment. It can be renamed.
BOOL
This member acts as padding to ensure byte alignment. It can be renamed.
BOOL
This member acts as padding to ensure byte alignment. It can be renamed.
BOOL
This member acts as padding to ensure byte alignment. It can be renamed.
2
BOOL
This member acts as padding to ensure byte alignment. It can be renamed.
BOOL
This member acts as padding to ensure byte alignment. It can be renamed.
0 = DLR is not enabled
BOOL
1 = DLR is enabled
BOOL
This member acts as padding to ensure byte alignment. It can be renamed.
BOOL
This member acts as padding to ensure byte alignment. It can be renamed.
SINT
1
The status of the network.
SINT
1
The status of the network supervisor.
The offset in nanoseconds from the local clock to the system time. Use this value to
LINT
8
detect steps in time. This value updates when a PTP update is received.
The most recent time the LocalClockOffset is sampled. The initial value is zero and the
LINT
8
first time stamp occurs when the module synchronizes with the master clock.
SINT[8]
8
The EUI-64 Identity of the CIP Sync Grand Master clock that the module is synced to.
LINT
8
The most recent time an SA power fault occurred.
LINT
8
The most recent time an LA power fault occurred.
The most recent time the module reached a higher temperature than its operating
LINT
8
limits.
The most recent time the module temperature transitioned above the Critical
LINT
8
Temperature.
LINT
8
The most recent time an internal fault condition occurred.
User-defined
16
User-defined data type for AB:Ethernet_Port_Channel_D:0, see
User-defined
16
Rockwell Automation Publication 5032-UM001A-EN-P - April 2023
Table