Appendix D
Module Diagnostic Assembly
Table 41 - Diagnostic Assembly Instance 32779
Name
ChannelMode12
ChannelMode13
ChannelMode14
ChannelMode15
Pad
AB:5000_IOLM_Channel:D:0 Ch12
AB:5000_IOLM_Channel:D:0 Ch13
AB:5000_IOLM_Channel:D:0 Ch14
AB:5000_IOLM_Channel:D:0 Ch15
Table 42 - Diagnostic Assembly Instance 771
Name
RunMode
InfoBits_Pad1
DiagnosticActive
InfoBits_Pad3
InfoBits_Pad4
InfoBits_Pad5
InfoBits_Pad6
InfoBits_Pad7
DiagnosticSequenceCount
TCPConnections
CIPConnections
CIPLostPackets
CIPTimeouts
HMIPacketRate
IOPacketRate
EthernetErrors
CPUUtilization
112
5. Diagnostic IO-Link Master Assembly D
- Instance ID = 0x800B (32,779)
- Size = 232 bytes
Follow the information in
Data Type
Byte
Valid Values
SINT
1
The operating mode of the channel.
SINT
1
The operating mode of the channel.
SINT
1
The operating mode of the channel.
SINT
1
The operating mode of the channel.
DINT
4
This member acts as padding to ensure byte alignment. It can be renamed.
User-defined
56
User-defined
56
User-defined type for AB:5000_IOLM_Channel:D:0, see
User-defined
56
User-defined
56
6. Diagnostic Counters Ethernet Adapter Assembly
- Instance ID = 0x303 (771)
- Size = 28 bytes
Follow the information in
Data Type
Byte
Valid Values
0 = Idle
BOOL
1 = Run mode
BOOL
This member acts as padding to ensure byte alignment. It can be renamed.
0 = No diagnostics active
BOOL
1 = One or more diagnostics are active or the prognostics threshold is reached
1
BOOL
This member acts as padding to ensure byte alignment. It can be renamed.
BOOL
This member acts as padding to ensure byte alignment. It can be renamed.
BOOL
This member acts as padding to ensure byte alignment. It can be renamed.
BOOL
This member acts as padding to ensure byte alignment. It can be renamed.
BOOL
This member acts as padding to ensure byte alignment. It can be renamed.
-128...+127
SINT
1
The value of 0 is skipped except during module power-up.
INT
2
Total number of active TCP connections.
INT
2
Total number of active CIP connections.
DINT
4
Total number of lost CIP packets.
DINT
4
Total number of connection timeouts that have occurred.
DINT
4
The packet rate between the module and HMI.
DINT
4
The packet rate to and from the module.
DINT
4
Total number of Ethernet errors.
INT
2
Total CPU load.
Rockwell Automation Publication 5032-UM001A-EN-P - April 2023