Chapter 6
Configure the IO-Link Device
72
Device Correlation Check
Device Correlation Check triggers when you select Correlation or when the Configuration view
is selected while ADC is disabled. If a difference is detected, the following message prompt
appears.
You can decide which values (device or project) to use and apply the selected values to resolve
conflicts.
If you select "Use Project Values", the current project values are saved to the project
and immediately applied to the device, regardless of whether the device is inhibited or
uninhibited.
If you select "Use Device Values", the values of the configuration parameters replace
the project values. Select Apply to save the values to the project or Cancel to revert to
the original project values.
IMPORTANT After you select "Use Device Values", you must select Apply to save the
new values into the project.

Parameters View

The Parameters view displays all device parameters and their device values. Information in
this view is only populated when the project is online.
Use Insert Factory Defaults to revert read/write values of all non-configuration parameters to
the default values that are defined in the IODD.
Use this view to complete the following tasks:
View device values of all device parameters.
Although you cannot change configuration parameters of the device in this view, you
can verify their actual values. Use the Configuration view to change the values of
configuration parameters.
Change non-configuration read/write parameters.
The new values are only set to the device when you select Set.
For more information, see
Perform a command that is supported by the device by selecting the associated button.
Rockwell Automation Publication 5032-UM001A-EN-P - April 2023
IO-Link Device Parameters Classification on page
33.