IO-Link Master Module and IO-Link Device Tag Definitions
Table 31 - IO-Link Master Module Event Input Tags (Continued)
Name
Eventxx.CounterxxDone
Eventxx.PtxxFault
Eventxx.CounterxxFault
Table 32 - IO-Link Master Module Event Output Tags
Name
Eventxx.En
Eventxx.EventRisingEn
Eventxx.EventFallingEn
Eventxx.LatchEn
Eventxx.ResetEvent
Eventxx.IndependentConditionTriggerEn BOOL
Eventxx.EventNumberAck
Eventxx.PtxxDataSelect
Eventxx.CounterxxSelect
Eventxx.PtxxDataValue
Eventxx.CounterxxValue
104
Data Type
Definition
When set, indicates the corresponding counter Done bit
BOOL
(rising or falling depending on configuration) triggered
the event.
Indicates that channel data is inaccurate and cannot be
trusted for use in the application.
BOOL
For more information, see
page
17.
When set, indicates that the corresponding counter had
BOOL
a fault indicated when the event occurred.

Event Output Tags for IO-Link Master Module

Table 32
describes the available event output tags ('EO').
Data Type
Definition
When set, the corresponding event trigger definition is
BOOL
active and events are triggered when conditions match
the definition.
BOOL
Triggers an event each time a condition change results
in conditions that match the event trigger definition.
BOOL
When set, events are latched until acknowledged.
A new event is lost if the previous event has not been
BOOL
acknowledged.
When not set, new events overwrite old events.
A transition from 0 to 1 resets all events and clears the
BOOL
event queue on the channel.
Determines whether an input state change or a pattern
of input state changes triggers an event.
The controller writes back EI.Eventxx.EventNumber into
DINT
EO.Eventxx.EventNumberAck to indicate receipt of the
event.
Determines whether the input participates in the
BOOL
event trigger.
Determines whether the counter participates in the
BOOL
event trigger.
Determines the state of the input that triggers
BOOL
the event.
Determines the state of the counter that triggers
BOOL
the event.
Rockwell Automation Publication 5032-UM001A-EN-P - April 2023
Valid Values
0 = Corresponding counter Done bit did not trigger the
event
1 = Corresponding counter Done bit triggered the event
0 = Good
1 = Bad, causing fault
If the tag is set to 1, you must troubleshoot the module to
Fault and Status Reporting on
correct the cause of the inaccuracy.
IMPORTANT: Once the condition that causes the tag to
change to 1 is removed, the tag automatically resets to 0.
0 = Corresponding counter did not have a fault indicated
when the event occurred
1 = Corresponding counter did have a fault indicated
when the event occurred
Valid Values
0 = Event trigger definition is not active and events are
not triggered when conditions match the definition
1 = Event trigger definition is active and events are
triggered when conditions match the definition
When EO.Eventxx.IndependentConditionTriggerEn = 0
Trigger event (EventRisingEn, EventFallingEn):
• Disable (0, 0)
• On input transition to match pattern (1, 0)
• On input transition to not match pattern (0, 1)
• On input transition to match or not match pattern (1, 1)
When EO.Eventxx.IndependentConditionTriggerEn = 1
Trigger event (EventRisingEn, EventFallingEn):
• Disable (0, 0)
• On transition (1, 0)
• On inverted transition (0, 1)
• On any transition (1, 1)
0 = Event is not latched
1 = Event is latched
0 or 1
0 = Event is triggered when all participating inputs in the
event trigger achieve their configured values
1 = Event is triggered when any participating input in the
event trigger achieves their configured value
All values
0 = Does not participate in event trigger
1 = Participates in event trigger
0 = Does not participate in event trigger
1 = Participates in event trigger
0 = Off
1 = On
0 = Not done
1 = Done